Coatings

Berlinkauf Trade Leads / Chemical / Coatings
Directory Trade Leads Rated Visits Date Images
Coatings
 sell chemical plating, electrophoretic painting
anodizing, hardcoat anodizing, chromate conversion, electroplating, electropolishing, passivation, selective masking, abrasive blasting, chemical plating, electrophoretic painting

0 (#0) 10 2008.12.30 sell chemical plating, electrophoretic painting
Coatings
 sell selective masking, abrasive blasting
anodizing, hardcoat anodizing, chromate conversion, electroplating, electropolishing, passivation, selective masking, abrasive blasting, chemical plating, electrophoretic painting
0 (#0) 9 2008.12.30 sell selective masking, abrasive blasting
Coatings
 sell electropolishing, passivation
anodizing, hardcoat anodizing, chromate conversion, electroplating, electropolishing, passivation, selective masking, abrasive blasting, chemical plating, electrophoretic painting
0 (#0) 7 2008.12.30 sell electropolishing, passivation
Coatings
 sell chromate conversion, electroplating
anodizing, hardcoat anodizing, chromate conversion, electroplating, electropolishing, passivation, selective masking, abrasive blasting, chemical plating, electrophoretic painting
0 (#0) 9 2008.12.30 sell chromate conversion, electroplating
Coatings
 sell anodizing, hardcoat anodizing
SanYong Aluminum Surface Finishing Factory has been a premier finishing supplier to China Aluminum industry for over 14 years. Since 1994, continuous improvement to uphold the highest standards has been a corporate objective. We specialize in anodizing, hardcoat anodizing, chromate conversion, electroplating, electropolishing, passivation, selective masking, abrasive blasting, chemical plating, electrophoretic painting etc.

0 (#0) 9 2008.12.30 sell anodizing, hardcoat anodizing
Coatings
  High wear resistance additives of coatings
Chemical formula: Si3N4 amorphous
Purity: >99.0%
[O] <0.62%
free [Si] <0.2%
APS: 20 nm
SSA: 115 m2/g
True density: 3.4 g/cm3
Bulk density: 0.05 g/cm3
Crystal cell: amorphous
Color: White
Shelf time: 24 months

Chemical formula: SiC beta
Purity: 99.0%
[O] <0.6%
free [Si] <0.2%
APS: 30 nm, 50nm
SSA: 60-80 m2/g
True density: 3.22 g/cm3
Bulk density: 0.08 g/cm3
Crystal cell: Cubic
Color: Green
CAS No.: 409-21-2
EINECS Number: 206-992-8
Form: Powder
Solubility in / Miscibility with Water: Insoluble
Hazard class: No
Shelf time: 24 months
0 (#0) 89 2008.08.07  High wear resistance additives of coatings
Coatings
 Ultra Fine Powder Coatings
FLUOROFINE 90
POLYFINE 3000
0 (#0) 158 2008.06.10 Ultra Fine Powder Coatings
Coatings
 RTV Insulator Anti Flashover Coating
RTV The insulator antifouling Flashover the coating technical specification data sheet



Item

DL/T 627 Standard

Technical Property
&#65288;Test Value &#65289;

Test Method
Outward appearance

Does not have the obvious mechanical impurity, does not have the cotton wool shape precipitation, after the solidification smooth smoothly does not have the air bubble

White (red, ash, is transparent) the color mobile liquid, the coating smoothly does not have the air bubble

GB 1721-79
Solid content %

&#8814;22

55

GB 1725-89
Viscosity s

15~60

30

GB 1723-93
Surface resistivity
&#937;?m

&#8814;1?1012

1.8?1016

GB 1410-78
Volume resistivity &#937;?m

&#8814;1?1014

1.5?1014
Relative permittivity dielectric lose tangent value

&#8815;3.0

2.35

GB 1409-78
&#8815;0.3%

3.0?10-3
Breakdown field value MV/m

&#8814;15

25.6

GB 1408-78
Arc resistance s

&#8814;180

190

GB 1411-78
Resistance to track
and erosion TMA

&#8805;2.5

1A 2.5

GB 6553-86
Adhesion ability &#65288;drawing the cycle method &#65289;

No less 2 level

1~2 level

GB 1720-89
Abrasion resistance g

&#8815;0.05

qualified;

GB 1768-89
Rate of water absorption
%

&#8815;0.25

0.16

GB 1738-89
Hydrophobicity

Hydrophobic angle >90?

111.6?

DL/T627-1997
Corrosion proof

Under the acid, the alkali, the salt and the transformer oil function do not have the corrugation, falls off, bubbles, changes color and so on

The experiment does not have the corrugation to fall off bubbles changes color the phenomenon

GB 1739-89
GB 1763-89
The labor frequency arc-over voltage (dryly flashover , wet flashover ) KV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Have coat 90.3 ,
no coat 89.5

GB 775-87
Have coat 52.0 ,
no coat 49.6
Flashover resistance

U1&#65288;have paint coat&#65289;/U2
&#65288;no paint coat &#65289;>1.5

2.34&#65288;average&#65289;

GB 4585.1-84
The environment aging performance resistance

The coating should not be cracked under the natural condition, the pulverization, the skin and falls off

After the sample moves for 10 years the coating to be complete, has the good hydrophobic character

GB11206-89
Artificial accelerate ageing

Coating after 1000h artificial accelerated ageing test, is intermediate at least

1000h the salt-fog test does not have has flowed the severance according to GB/T1766 evaluates is 1 level

GB1865-80
Heat resistant denaturation experiment (adhesive force)

Bears 5 times of temperature cycles , the experiment but does not damage

Translation failed! please try again.

DL/T627-1997
Vulcanizing time

Surface dry up &#8815;30 min

Surface dry up 25 min

GB 6753.2-86
Full dry up &#8815;7days

Full dry up 72h

0 (#0) 218 2008.05.28 RTV Insulator Anti Flashover Coating
Coatings
 PRTV coating
PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating Technology parameter data sheet



Items

Q/HGH 019-2004 Standard

Technical Property &#65288;Test&#65289;

Test method
Outward appearance


Does not have the obvious mechanical impurity and the cotton wool shape, The coating should level, be smooth also does not have the air bubble

Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble

GB 1721-1979
Viscosity s

100~200

160

GB 1723-1993
Dielectric Strength kV/mm

&#8814;25

32.3

GB 1408-1978
Surface resistivity &#937;?m
Volume resistivity &#937;?m

&#8814;1?1012

4.25?1013

GB 1410-1978
&#8814;1?1014

2.92?1015
Relative permittivity dielectric lose tangent value

&#8815;3.0

2.7

GB 1409-1978
&#8815;0.3%

2.5?10-3
Arc resistance s

&#8814;180

217

GB 1411-1978
Electricity wear and tear leaks

AC
Alternating current

&#8814;TMA 4.5

1A 4.5

GB 6553-1986
DC
Direct current

&#8814;TMA 3.5

1A3.5
Adhesion ability

Cementation shearing strength MPa

&#8814;3.0

4.7

GB 13936-1992
Cycling method level

No less 2 level

1

GB1720-1989
Abrasion resistance g

&#8815;0.05

0.035

GB 1768-1989
Ratio of Water absorption %

&#8815;0.25

0.15

GB 1738-1989
Hydrophobicity

Hydrophobic
and level

Qav&#8805;100?Qmin&#8805;90?HC1~2

106?~109? HC1

DL/T810-2002
Lose property 96h

Qav&#8805;90?Qmin&#8805;85?HC3~4

Non showing loss
recovery characteristic

t&#8804;24h


Water repellency characteristic 96h

Qav&#8805;110?Q min&#8805;100?HC2~3

14 h Hydrophobicity reach HC1 110?~115?
Erosion Resistance Test

Acid , alkali and salt , 80&#8451;24 h

Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level

GB 1763-1989
transformer oil 105&#8451;24 h

Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level

GB 1739-1989
Labor frequency arc-over voltage

Dry arc-over voltage kV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Paint-coat 79.2 , no 75.9

GB 775-1987
Wet arc-over voltage kV

Paint-coat 61.9, no 55.9
Flashover resistance test

U1(have paint-coat )/U2(no paint-coat )&#8805;2.0

U1 /U2 =2.23

GB 4585.1-1984
Heat resistant denaturation experiment -40&#8451;~+80&#8451;&#65292;2.5h?5 times

The coating should not damage, The adhesion inspection is not lower than 2 levels

After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level

DL/T627-1997
Salt Spray test 1700 h

The test specimen does not surpass 3 time has flowed the severance

After 1800h&#65292;Does not have has flowed the severance

GBT5892-2003
GB/SV023-2003
Does not have leaks the mark, The electricity wear and tears have not reached the porcelain glaze

Does not have leaks the mark, The wear and tears have not reached the glazed surface
Hydrophobic migration characteristic HC2~3 level

HC1~2 level
A row line of experiment passes &#8805;3.0MPa

3.5 MPa
Flame Resistance

FV-O level

FV-O level

GB/T13488-92
The longitudinal strength and pulls apart the elongation ratio

Strength MPa

&#8814;4.0

5.5

GB/T528-1988
elongation %

No less 350

390
peel strength kN/m

&#8814;12.0

17.5

GB/T529-1988
Hardness (Shao )

35~55

46

GB/T531-1999
Vulcanizing time

Surface Dry up min

20~50

35

GB6753.2-1986
Full dry up h

&#8815;72

65
storage stability 50&#8451;

&#8805;45days

After 60 days &#65292;A row line of experiment passes

GB6753.3-1986
Self Clearance property [Only requests antifouling]

After the dirty fluid cementation is dry, Strips the intensity &#8815;3kPa(1 level )

Peel off strength 2.3kPa(1 level )

QB/SV021-2003
Anti ?icing property [Only requests to guard against the ice]

Anti- regelation (measure)

Paint-coat ice cover measure /no paint-coat &#8815;30%

18.3%

QB/SV022-2003
hydration property

DC value &#8814;90%

91.2%


0 (#0) 175 2008.05.28 PRTV coating
Coatings
 Industrial coating
Industrial coating
0 (#0) 263 2007.10.19 Industrial coating
Coatings
 Exterior wall coating
Exterior wall coating
0 (#0) 294 2007.10.19 Exterior wall coating
Coatings
 Interior wall coating
Interior wall coating
0 (#0) 299 2007.10.19 Interior wall coating
Coatings
 RTV Insulator Anti Flashover coating
The silicon valley brand sign RTV insulator anti flashover the coating to pass, the provincial level appraisal, The nation anti Flashover the expert group to appraise,ISO9001 International quality system authentication and sign DL/T 627 complete patterns experiments; its performance index has achieved the international advanced level
0 (#0) 348 2007.09.21 RTV Insulator Anti Flashover coating
Coatings
 PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
it is a kind of electrical power system uses the new electrical function material, it’s specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger then to design, It’s developed jointly by the North China electric power academy of science with our company successfully.
0 (#0) 335 2007.09.21 PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
Coatings
 Metal anticorrosion fluorine silicon coating
-
0 (#0) 345 2007.09.17 Metal anticorrosion fluorine silicon coating
Coatings
 Organ silicon flame-resistant heat conduction high voltage insulation coating
-
0 (#0) 285 2007.09.17 Organ silicon flame-resistant heat conduction high voltage insulation coating
Coatings
 RTV Insulator Anti Flashover coating
-
0 (#0) 272 2007.09.17 RTV Insulator Anti Flashover coating
Coatings
 PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
-
0 (#0) 294 2007.09.17 PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
Coatings
 Organ silicon flame-resistant heat conduction high voltage insulation coating/Metal anticorrosion fl
see above
0 (#0) 496 2007.06.08 Organ silicon flame-resistant heat conduction high voltage insulation coating/Metal anticorrosion fl
Coatings
 RTV Insulator Anti Flashover coating/PRTV outside power equipment insulates with takes shape permane
RTV
PRTV
0 (#0) 485 2007.06.08 RTV Insulator Anti Flashover coating/PRTV outside power equipment insulates with takes shape permane
Coatings
 DSA-1 Surface Active Agent for Drilling Fluid/SFB-1 Biology Thickening Agent for Drilling Agent
SFB-1
DSA-1
0 (#0) 529 2007.06.08 DSA-1 Surface Active Agent for Drilling Fluid/SFB-1 Biology Thickening Agent for Drilling Agent
Coatings
 SF Fluorine Silicon Filtrate Reducer for Drilling Fluids/Silicon Stability Agent for Drilling Fluids
SF
0 (#0) 449 2007.06.08 SF Fluorine Silicon Filtrate Reducer for Drilling Fluids/Silicon Stability Agent for Drilling Fluids
Coatings
 SF260 High-temperature Drilling Fluids Thinner/SF200P Fluorine silicon High-temperature Drilling Flu
SF200
SF260
0 (#0) 448 2007.06.08 SF260 High-temperature Drilling Fluids Thinner/SF200P Fluorine silicon High-temperature Drilling Flu
Coatings
 SF150 Fluorine Silicon Drilling Fluids Thinner (powder)
SF150P
0 (#0) 473 2007.06.08 SF150 Fluorine Silicon Drilling Fluids Thinner (powder)
Coatings
 sell AR607Pure Polyester Dulling Resin
AR607Pure Polyester Dulling Resin

AR607 is propylene ester resin which contains epoxy. It is one kind of outdoors dulling-resin powder coating. It has good dulling effect and can obtain gloss between 1 - 60% randomly, and it is suitable for dulling gloss between 1 - 30% outdoors pure polyester prowder coating.
Typical characteristics:.

-Fine levelling performance.

-Splendid weathering resistance, saltfog resistance, fire resisting quality and yellow stain resistance.

-Strong anti-shake trait
0 (#0) 351 2007.06.07 sell AR607Pure Polyester Dulling Resin